Many of these products are approved for installation with Strong-Drive® SD Connector screws. Model No. If the anchor doesn’t install completely, remove it from the hole, make certain that all the dust is removed from the hole or drill the hole deeper so that the dust can settle below the anchor. Re-install the anchor by hand to avoid cross threading from occurring. Each anchor bolt requires a standard-cut washer. The Simpson Strong-Tie® Titen HD® heavy-duty screw anchor does not require a washer.

Considered a post-installed concrete fastener, the Titen HD anchor needs to be located a minimum distance from an unsupported edge. Since this is not an expansion anchor, the minimum distance from an unsupported edge is 1-3/4-inches for all diameters. Meet the Titen Turbo™, the next‑generation concrete and masonry screw anchor from Simpson Strong‑Tie. Its revolutionary, patented, Torque Reduction Channel traps dust where it can’t obstruct thethread action, drastically reducing binding, stripping or snapping. From fully tested and engineered connectors and clipsSimpson Strong-Tie ® provides comprehensive structural solutions for cold-formed steel construction. From steel-to-steel connections to full-scale lateral solutions and curtain wall connectors, we remain committed to developing new technology that helps to advance the cold-formed steel industry. Refer to a chart that provides the diameter of the anchor, the recommended fixture, the hole diameter, and the wrench size before installation.

The drill bit used to drill the hole for the anchor must meet ANSI standards. Hole size is equal to anchor size. The diameter of the anchor being installed is equal to the hold diameter that is drilled into the base material. For example, if the Titen HD anchor is 3/8-inch, then the hole must be 3/8-inch. Align the hole in the fixture with the hole in the base material and then insert the Titen HD anchor through the fixture hole and into the hole in the base material. Post installed inspection of the Titen HD® heavy-duty screw anchor is simple because the length of the anchor is stamped on the head of the anchor. During an inspection, the embedment depth of any particular anchor can be determined by subtracting the length of the Titen HD® heavy-duty screw anchor above the surface of the base material from the total length of the anchor. Drill Bit Requirements

From testing to service to availability, everything we do is engineered to ensure your project's success. With every product, you know you are getting the quality, value, service and on-time delivery that we have built our reputation on for the past 60 years. The drill bit used for drilling a hole in the base material for the Titen HD® heavy-duty screw anchor must meet ANSI standards. Hole size is equal to anchor size. The diameter of the Titen HD® heavy-duty screw anchor being installed is equal to the hole diameter that must be drilled into the base material. If the Titen HD® heavy-duty screw anchor is 3/8” then a 3/8” hole must be drilled into the base material using a bit that meets ANSI standards. Hole Size Prescriptive" denotes spacing requirements per the IEBC and designs per the IRC and conventional provisions of the IBC.The anchor has been heat-treated to create tip hardness for better cutting. It can be installed using a standard-size ANSI tolerance drill bit and cuts into concrete with 50 percent less torque than other anchors. Spacing between the anchor and an unsupported edge is less than other types of anchors because the Titen HD anchor is not an expansion anchor and does not apply energy against the base material. As a result, the minimum spacing required for all diameters of the Titen anchor is 3-inches.

The Titen HD stainless-steel screw anchor for concrete and masonry is ideal for when the job calls for fast and efficient installation in multiple types of environments. The Titen HD stainless steel is a state-of-the-art anchor solution that combines the long-lasting corrosion resistance of Type 300 Series stainless steel with the undercutting ability of heat-treated carbon-steel cutting threads. Spacing requirements for the Titen HD® heavy-duty screw anchor are less between anchors and an unsupported edge because the Titen HD® heavy-duty screw anchor is not an expansion anchor and does not exert force against the base material. The minimum spacing requirements for all diameters of the Titen HD® heavy-duty screw anchors is 3” Titen HD® Minimum Edge Distance Patented Torque Reduction Channel that traps dust where it can’t obstruct the thread action, reducing the likelihood of binding in the hole

Anchor Designer™ Webinar

With a hammer drill and a carbide bit that meets ANSI standards and the same diameter as the Titen HD® heavy-duty screw anchor being installed, drill a hole in the base material. Drill the hole a minimum of 1/2” deeper than the Titen HD® heavy-duty screw anchors will penetrate. The hole in the fixture needs to be larger in diameter than the diameter of the Titen HD® heavy-duty screw anchor being installed. It is very important to make sure that the Titen HD® heavy-duty screw anchor being installed will fit through the fixture hole before the hole in the base material is drilled. See the chart below for the dimensions of the recommended hole diameter in the fixture: Titen HD® Diameter Nominal embedment depth for post-installed anchors into concrete must be 4" for SET-3G™ or AT-XP®, or use THD50400H Titen HD® screw anchors. Anchorage into CMU is per designer. For stainless-steel fasteners, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors. The anchor includes a hex-washer head for a cleaner installed appearance. No separate washer is necessary unless it is required by code.

It is easy to remove, so it’s ideal for temporary anchoring of formwork, bracing, or for applications where fixtures may be moved. Corrosion Resistant— For dry, interior applications, carbon-steel corrosion is not a risk, but in any kind of exterior, coastal or chemical environment the anchor would be susceptible to corrosion. With the introduction of the THDSS, there is finally a state-of-the-art anchor solution that combines the corrosion resistance of Type 300 Series stainless steel with the undercutting ability of sacrificial heat-treated carbon-steel cutting threads. Models THD37134H and THD37212H do not meet minimum embedment depth requirements for strength design and require maximum installation torque of 25 ft. – lb. using a torque wrench, driver drill or cordless 1/4" impact driver with a maximum permitted torque rating of 100 ft. – lb. Availability with either a hex head or, for a smoother installed profile, a T30 6-lobe-drive countersunk head Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth plus minimum hole depth overdrill (see table below) to allow the thread tapping dust to settle, and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and the dust from drilling and tapping.

Building Strong Blog

A space of 1” under the head is unthreaded on two of the Titen HD® heavy-duty screw anchors to allow for installation into the tilt-up braces used in tilt-up construction. The 3/4” x 6” and the 3/4” x 7 are designed specifically for this type of application. Titen HD® Installation